Free tool · no email required

Make your tarp requirements easier to check

In short

Choose your load family and service. Get a specification block with published fabric values, construction requirements and reception checks. It puts the fabric weight you require in writing; measuring the delivered fabric checks whether the order was met. Paste the block into any request for quote, ours or anyone else's.

01

Your loads

A starting reference only. Load measurements and finished fit still need confirmation.

Decides the drop. Leave empty to keep the drop as an open line on the block.

Entered geometry is yours. Fabric numbers are published references with sources, not confirmation of a supplied product or batch.

02

The block to paste into your RFQ

Your request at a glance

Your inputs
Documentary references
Still to agree
Finished geometry, material by panel, seams, hardware layout, tolerances, sample and test method. The supplier's confirmation and the received-batch evidence are separate records.
Read the complete block, including sources and open points
 

First personal reply within 2 business days, with clarifying questions or next steps.

Conceptual illustration. You can pause the movement.

Static view: reduced motion is enabled.

Measure the property you are specifying

Fabric weight per area

Use the mass and area of an identified fabric specimen Known area mass

Specimen mass ÷ specimen area. Keep the area units consistent with g/m² or oz/yd². Identify the proposed finished fabric, including its coating where specified.

Agree the specimen, conditioning, method and tolerance before taking a sample. This drawing is not a sampling protocol or a test result.

Whole-cover weight

A complete cover includes more than the fabric specimen Fabric + construction

Useful for handling and an agreed screening check. Hems, reinforcement and hardware contribute to the total. It does not establish the fabric's weight per area.

Compare the approved construction and the identified specimen separately. No resistance or service life is inferred from these measurements.

Conceptual measurements, not to scale. Record buyer requirements, supplier confirmation and received-batch evidence separately.

Conceptual illustration. You can pause the movement.

Static view: reduced motion is enabled.

Keep each material on its own specification line

Assign the fabric to the identified part Main coverRequirement: 18 oz/yd² Other panel, if specifiedMaterial to confirm

The block requests an 18 oz finished coated fabric. Identify every proposed panel and its material on the supplier's drawing; a reference sheet does not confirm the supplied construction.

When a listing gives different main-cover and drop-flap weights, keep those properties separate. An 18 oz reference report does not specify a lighter panel.

Confirm panel boundaries, joins and the finished dimensions on the approved drawing. Ask for an identified sample of each proposed material.

Conceptual material groups. Box sizes, colors and positions do not represent panel area, thickness or a production pattern. Selected listing values remain market references.
What makes a configuration checkable at reception?

Keep your requirement, the supplier's written confirmation and the received batch record separate. Use the same configuration ID and drawing revision throughout.

RequirementWritten confirmationReception record
Top, sides and flapPanel map and proposed fabric for each panelCompare construction with the approved drawing
Finished coated weight per areaUnits, agreed tolerance and representative fabric sampleMeasure the fabric; whole-piece weight is only a screening check
D-rings, grommets, hems and seamsCounts, spacing, reinforcement and seam method for this configurationCount and photograph the agreed layout; any pull test needs an agreed method and acceptance criterion
Finished geometryNamed edges, dimensions, tolerance and drawing revision; coil pattern and openings where applicableMeasure against the agreed drawing
Test propertiesMethod, specimen, conditions and result for the proposed materialA published fabric sheet is not a test report for the received batch

A welded seam description alone does not confirm water performance. Agree the method, acceptance criterion, sampling and evidence before ordering. No default tolerance or acceptance threshold is assumed.

This tool covers flatbed tarps. For hay, use the round bale stack size calculator and the hay tarp fabric and fixing specifications.

Why these exact values

Typical values for Trivantage C18403 Super 18 vinyl-coated polyester, sheet issued September 6, 2010. A dated material reference, not a specification for all 18 oz fabrics or a test of the proposed batch. Read the material reference sheet (PDF). Agree any required performance values, specimens, methods and acceptance criteria with the supplier. A reference sheet does not establish the performance of a retailer's cover or of a proposed batch. Practitioners report differences between ordered fabric and received tarps. Weight per area is a property to verify; it does not by itself prove waterproofness or abrasion resistance. Confirm coating, construction and the relevant test results separately.

Construction to agree on the drawing and sample: Specify seam type, reinforcement and hardware supports on the drawing and approved sample. Confirm any water-resistance claim for the finished assembly separately: fabric coating alone does not describe seams or openings. Agree specimen, method and acceptance criteria for any destructive test.

Our sourcing enquiries also returned lighter fabric options. Those are factory claims we have not verified against a published spec sheet, so this tool does not write them into a spec: if your case genuinely calls for lighter fabric, the honest path is a sample verified on a scale before the order, and we say so on the quote.

Fabric and dimensions are separate decisions. Use the flatbed tarp size guide to confirm width, side drop and end flaps before attaching this block to a quote.